Sewing Machine, Industrial Cylinder Arm Walking Foot, (Techsew TS-2750) ID:183: Difference between revisions

→‎Specs: added thread sizes for needles
(→‎Startup: adding bobbin direction clarifiers)
(→‎Specs: added thread sizes for needles)
Line 28: Line 28:
* Needle  
* Needle  
** System: 135X17 (DPX17)
** System: 135X17 (DPX17)
** Size: #18 to #24 gauge
** Size: 18 to 24
* Thread  
* Thread  
** Top: Right Twist (Z)  
** Top: Right Twist (Z)  
Line 40: Line 40:


Playlist: https://www.youtube.com/watch?v=Qc7WBXREGpQ&list=PL4iVwH6cbP578HmtFcGT_cfE5wodn1RWf
Playlist: https://www.youtube.com/watch?v=Qc7WBXREGpQ&list=PL4iVwH6cbP578HmtFcGT_cfE5wodn1RWf


Oiling: https://www.youtube.com/watch?v=IqG6p0OJkZo
Oiling: https://www.youtube.com/watch?v=IqG6p0OJkZo
Line 53: Line 52:


'''Caution:''' '''The foot pedal WILL STILL OPERATE THE MACHINE for a few revolutions if the controller has recently been powered off.''' The servo controller will retain a moderate capacitor charge after powering off.  To drain this charge, firmly hold the hand-wheel while gently depressing the pedal - the motor will try to turn at low speed but will quickly run out of power. Once the capacitors are drained, the unit is safe to work on.
'''Caution:''' '''The foot pedal WILL STILL OPERATE THE MACHINE for a few revolutions if the controller has recently been powered off.''' The servo controller will retain a moderate capacitor charge after powering off.  To drain this charge, firmly hold the hand-wheel while gently depressing the pedal - the motor will try to turn at low speed but will quickly run out of power. Once the capacitors are drained, the unit is safe to work on.
{| class="wikitable mw-collapsible"
|+Needle and Thread compatibility
|Metric Needle Size
|Needle  size
|Compatible Thread size
|-
|100
|16
|30, 46, 69
|-
|105
|17
|30, 46, 69
|-
|110
|18
|46, 69
|-
|120
|19
|69, 92
|-
|125
|20
|69, 92
|-
|130
|21
|69, 92
|-
|140
|22
|92, 138
|-
|160
|23
|138
|-
|180
|24
|138, 207
|}


=== Startup ===
=== Startup ===