Embroidery machine, CNC (Tajima TEJT II-C NEO 1501) ID:144: Difference between revisions

Jump to navigation Jump to search
Line 48: Line 48:
Clear previous jobs stored in the memory:
Clear previous jobs stored in the memory:


*Each time a job is loaded from the USB stick the job is transferred to the internal memory of the Tajima.  
*Each time a job is loaded from the USB stick the job is transferred to the internal memory of the Tajima.
*In Memory Mode - Multi, the job is added to the list of jobs.
*In Memory Mode - Multi, the job is added to the list of jobs.
*In Memory Mode - Single, the new job overwrites the last job held in internal memory.  
*In Memory Mode - Single, the new job overwrites the last job held in internal memory.
*When the internal Tajima memory is full a 2BA error will occur after pressing Data and choosing the job file from the USB.
*When the internal Tajima memory is full a 2BA error will occur after pressing Data and choosing the job file from the USB.
*The 2BA error may occur instantly or near the end of the file load process depending on when the limit is reached.  
*The 2BA error may occur instantly or near the end of the file load process depending on when the limit is reached.
*If the internal memory is very full, pressing the Data button to pick a USB file will give no response as if the Data button is broken.  
*If the internal memory is very full, pressing the Data button to pick a USB file will give no response as if the Data button is broken.
*When the Tajima is too full to show the 2BA error, data can be deleted just as if the 2BA error had appeared.
*When the Tajima is too full to show the 2BA error, data can be deleted just as if the 2BA error had appeared.
*
*
*Press down to select
*Press down to select
*3. Delete Data to remove a single job or to  
*3. Delete Data to remove a single job or to
*5. Initial Memory - to remove all jobs from memory and initialize internal storage[[File:TajimaDataM1.png|none|thumb|Data Menu]][[File:TajimaDataM3.png|left|thumb|Data Menu 3]]<br />
*5. Initial Memory - to remove all jobs from memory and initialize internal storage[[File:TajimaDataM1.png|none|thumb|Data Menu]][[File:TajimaDataM3.png|left|thumb|Data Menu 3]]<br />


Line 74: Line 74:




<br />
 
 
There is no way to save a list of internal jobs out.
 
Keep a copy of your Jobs on a USB stick.
 
It is convenient if you are doing multiple jobs in a single session to keep them in internal memory.
 
Just remember jobs saved to the Internal Tajima memory may be cleared by the next member using the machine.
 
As a curtesy to the next user who may be a beginner and not know about 2BA error, clear the memory at the end of your session.
===Quick Start===
===Quick Start===
{{Warning|This "cheat sheet" is not a substitute for proper training and confidence in operating this very nice and expensive machine! If you're feeling unsure, ask for help!}}