Line 22: | Line 22: | ||
'''Tool holder type''': ER25 collets, we have 1/8", 1/4",3/8",1/2" (as of 05.11.2021) | '''Tool holder type''': ER25 collets, we have 1/8", 1/4",3/8",1/2" (as of 05.11.2021) | ||
Automatic tool changer: No | Automatic tool changer: No | ||
'''File units''': Default units are imperial. you may switch to metric using gcode commands, it is recommended that you export imperial code. | '''File units''': Default units are imperial. you may switch to metric using gcode commands, it is recommended that you export imperial code. | ||
File type accepted: .tap, .gcode, .txt | File type accepted: .tap, .gcode, .txt | ||
'''Machine control software suite''': Mach3 skinned with [http://www.physanon.com/pa-mach-3-screen-set/ physics anonymous Mach pack] | '''Machine control software suite''': Mach3 skinned with [http://www.physanon.com/pa-mach-3-screen-set/ physics anonymous Mach pack] | ||
Will do 3 axis moves?:Yes | Will do 3 axis moves?:Yes | ||
'''Hold down method''': Screws, nails, clamps(must make these). Vacuum table in the future. | '''Hold down method''': Screws, nails, clamps(must make these). Vacuum table in the future. | ||
Note that the hold-down table has a grid of threaded T-Nuts that | |||
Note that the hold-down table has a grid of threaded T-Nuts that can/should be used to hold down your material. If you wish to make your own sacrificial / holding system, simply prepare to fasten it down to this grid pattern. The spacing of the threaded nuts is 4.861" (123.63mm) on both the X and also Y axis. Wtf is that spacing? Why not a nice round English or Metric spacing? Well, that is the spacing of the T-channels in the underlying bed. Get used to it and make your templates. | |||
[[File:142-Precix-bed-Nuts-spacing.jpg|150x150px|Precix Mounting Nut Spacing]] | |||
'''Dust collection'''?: Yes, separate from main dust collector | '''Dust collection'''?: Yes, separate from main dust collector |