#Position gantry is in back left and bed is lowered.
#Position gantry is in back left and bed is lowered.
#'''ENSURE POWER IS OFF BEFORE MAINTENANCE.'''
#'''ENSURE POWER IS OFF BEFORE MAINTENANCE.'''
#Remove bed.  
#Remove bed.
#In all cleaning steps, do not spray any cleaners inside the laser. Spray onto cloth or paper towel outside of laser.
#In all cleaning steps, do not spray any cleaners inside the laser. Spray onto cloth or paper towel outside of laser.
#Clean inner and outer surfaces of laser cutter including window.  
#Clean inner and outer surfaces of laser cutter including window.  
Line 101: Line 101:
#*'''DO NOT USE ANY AEROSOL OR SPRAY LUBRICANT'''
#*'''DO NOT USE ANY AEROSOL OR SPRAY LUBRICANT'''
#*'''Currently using Permatec Ultra Slick multipurpose synthetic grease.'''
#*'''Currently using Permatec Ultra Slick multipurpose synthetic grease.'''
#Remove and clean lens.
#Remove and clean lens. Do not lose o-ring. Check direction of the lens (replace as it was if unsure.)
#Check condition of optics clean if necessary (again, ensure power is off.)
#Check condition of optics clean if necessary (again, ensure power is off.)
##Clean lens at the head of the laser tube
##Clean lens at the head of the laser tube
##Clean mirrors with q-tips and lens cleaning solution if available (use isopropyl alcohol if not)
##Clean mirrors with q-tips and lens cleaning solution if available (use isopropyl alcohol if not)
##If cleaning the optics, '''PROCEED TO ALIGNMENT'''
##If cleaning the optics, '''PROCEED TO ALIGNMENT'''
#'''Put on eye protection.''' Check laser alignment. Adjust if necessary.
#'''Put on eye protection.''' Check laser alignment. Adjust if necessary. [working notes - tape target to mirror 2 (left hand on gantry) - ]
##TODO: expound on mirror alignment tricks
###targets
##To reset Z height on laser head - Move Z axis bed to top. Put down piece of paper. Adjust laser head to just touch top focus on focus gauge
#Replace bed. Check it is level. Adjust if necessary.
#Check tension on all belts. Adjust if necessary.
#Check tension on all belts. Adjust if necessary.
#Inspect electronic components for operation including six limit switches (±X, ±Y, ±Z axis), lights and light wiring, electronics cooling fan
#Inspect electronic components for operation including six limit switches (±X, ±Y, ±Z axis), lights and light wiring, electronics cooling fan
#Replace bed. Check it is level. Adjust if necessary.
#Blow out dust from chiller radiator.
#Blow out dust from chiller radiator.


Line 128: Line 131:
Air tube hits the X-max limit switch on right side.
Air tube hits the X-max limit switch on right side.


Wish list - gloves, syringes for greasing bearings, brake cleaner, size set screw (M3?)
Wish list - gloves, syringes for greasing bearings, brake cleaner, size set screw (M3?). Laser cut targets (we are out of laser head targets)