Laser cutter, large (Rabbit Laser RL-80-1290) ID:6: Difference between revisions

m
Line 100: Line 100:
==Repair History==
==Repair History==


*Break/Fix log
Break/Fix log:
** Current status:  DOWN
*Current status:  DOWN
**Nov 24, 2016 - DOWN: Laser tube replaced, chiller pump is broken
*2016-11-24 - DOWN: Laser tube replaced, chiller pump is broken.
**Nov 13, 2016 - DOWN: Two new laser tubes ordered from the US.
*2016-11-13 - DOWN: Two new laser tubes ordered from the an American source.
**Nov 11, 2016 - DOWN: Chiller failure caused laser tube failure and destruction
*2016-11-11 - DOWN: Chiller failure.  Laser tube destroyed.
**Nov 7, 2016 - UP: Laser tube replaced with an aging, but unused tube that was donated from a scrap laser
*2016-11-07 - UP: Laser tube replaced with an aging, but unused tube that was donated from a scrap laser
**Nov 6, 2016 - DOWN: Chiller failure.  Laser tube destroyed (overheated and glass cracked)
*2016-11-06 - DOWN: Chiller failure.  Laser tube destroyed (overheated and glass cracked)


*Regular maintenance log
Regular maintenance log: