844
edits
Ian Oliver (talk | contribs) (→Specs: added more specs) |
Ian Oliver (talk | contribs) (more details) |
||
Line 5: | Line 5: | ||
|model=Fiac Airblok Series Compact 106 | |model=Fiac Airblok Series Compact 106 | ||
|serial=?? | |serial=?? | ||
|owner=STARS | |owner=William / STARS | ||
|loanstatus=Donated to Protospace | |loanstatus=Donated to Protospace | ||
|arrived=July 2012, December 2015 | |arrived=July 2012, December 2015 | ||
|location=Not fixed; probably in the metal shop | |location=Not fixed; probably in the metal shop | ||
|status= Working (repaired 2013-03-28, checked 2015-12-15) | |status= Working, but gauges are semi-broken (repaired 2013-03-28, checked 2015-12-15) | ||
|permission=Open to Members & Friends | |permission=Open to Members & Friends | ||
|certification=Demo/Notes Required | |certification=Demo/Notes Required | ||
Line 21: | Line 21: | ||
* Avoid using extension cords, may trip breakers. | * Avoid using extension cords, may trip breakers. | ||
* Before use, check drain valve underneath, should need to be closed. DO NOT overtighten. | * Before use, check drain valve underneath, should need to be closed. DO NOT overtighten. | ||
* After use, always drain tank. Use blowout valve first, then open drain valve underneath and leave open. DO NOT overloosen. Opening valve drains air completely but also water that has accumulated inside tank. If forgotten, tank will rust and eventually rupture. This is a big deal, remember to do it every time. | * '''After use, always drain tank.''' Use blowout valve first, then open drain valve underneath and leave open. DO NOT overloosen. Opening valve drains air completely but also water that has accumulated inside tank. If forgotten, tank will rust and eventually rupture. This is a big deal, remember to do it every time. | ||
==Specs== | ==Specs== | ||
Line 31: | Line 31: | ||
** 0.75 HP / 560 W (product line PDF) | ** 0.75 HP / 560 W (product line PDF) | ||
* Sound level: | * Sound level: | ||
** 71 | ** 71 [http://www.noise-measurement.nl/sound-power-pressure-dB(A)-SPL-SWL.htm dB L<sub>WA</sub>] (back panel) | ||
** 57 dB(A) (product line PDF) | ** 57 [http://www.noise-measurement.nl/sound-power-pressure-dB(A)-SPL-SWL.htm dB(A)] (product line PDF) | ||
** subjectively very quiet as compressors go; easy to talk over | |||
* Capacity: | * Capacity: | ||
** 1.5 US gallons (back panel) | ** 1.5 US gallons (back panel) | ||
Line 60: | Line 61: | ||
* 2013-02-02 - Danny fixed some stuff. | * 2013-02-02 - Danny fixed some stuff. | ||
* 2013-03-28 - Danny replaced the punctured hose and fittings, works great now. | * 2013-03-28 - Danny replaced the punctured hose and fittings, works great now. | ||
* 2015-12-15 - Matt F, Stan, and Ian checked the compressor upon its return and found it to work. | * 2015-12-15 - Matt F, Stan, and Ian O checked the compressor upon its return and found it to work. |